Remote modular system of IO high speed, performance and economic.
Remote modular system IO high speed, high performance and economic.
The system, from now reported with HSRIO, it allows the management di I/O remote from PC through connection LAN to high speed.
For remote I/O on intends a whole series of intelligent unity devoted to input functions / logical and analogical output, control motor, reading encoder, etc.
The choice of the connection type LAN allows to get two important performances:
- standard interface, that doesn’t ask for additional hardware for the connection with PC because everyone is already equipped.
- high speed data transfer
NETWORK:
- Ethernet Bus 10/100 MHz RJ45, relaunched towards local bus
synchronous serial high speed , or bus RS485 115 Kb/S - Very hih-speed protocol: 0,2 ms / CPU (ex: 5.120 input and 2.560 digitals output in 1 ms)
- Up to 250 CPU
- Up to 16 local and remote modules for CPU (up to 128.000 digital input and 64.000 digital output in 50 ms)
- Optional fiber optic connection
- Possible wireless connection (in case of not critical application)
- Possible internet connection (in case of not critical application)
- Ethernet network usable by other applications (in case of not critical application)
HARDWARE:
- 24 Vdc Power supply
- DIN rail assembly
- Extremely compact: 24-48 x 100 x 120 mm (w x h x l)
- Screw clamp terminal blocks and D-shell connectors (counters only)
- Economic, easy, hardy and fast system wiring
SOFTWARE
- Configuration and test tools
- Windows® and RTX® Drivers
- Softlogic, Motion control and SCADA hiPlc®
SAFETY
- Flash Memory holds systems configuration
- Configurable Outputs Watchdog
APPLICATIONS:
- multi-axis and high speed machines
- packaging, pallets handlers
- cartesian robots
- automatic storing machines
- building automation
- Testing
- etc..
HSRIO SYSTEM MODULES:
RMMA 10/20: (CPU module)
It is the Master form: ring of communications among PC and other forms
- CPU Master module: connecting PC with Ethernet interface
- 32 digital inputs 24 Vdc PNP
- 16 digital outputs 24 Vdc 100 mA PNP
- 1 interface CAN 2.0 1Mbit/S
- 48 x 100 x 120 mm (w x h x l)
RMIO10 (Local slave module synchronous)
- Slave module: local synchronous, or remote RS485
- 32 digital inputs 24 Vdc PNP
- 16 digital outputs 24 Vdc 100 mA PNP
- 2 counters 1 channel 24 Vdc 400 kHz (use digital inputs)
- 48 x 100 x 120 mm (w x h x l)
RMAD10 (Local slave module synchronous)
- Slave module: local synchronous, or remote RS485
- 24 digital inputs 24 Vdc PNP
- 12 digital outputs 24 Vdc 100 mA PNP
- 4 differential analogical inputs ±10 Vdc o ±20 mA, 12 bit
- 2 analogical outputs ±10 Vdc, 12 bit
- 48 x 100 x 120 mm (w x h x l)
RMEN10 (Local slave module synchronous)
- Slave module: local synchronous, or remote RS485
- 16 digital inputs 24 Vdc PNP
- 14 digital outputs 24 Vdc 100 mA PNP
- 1 encoder 3 differential channels 500 kHz
- 1 encoder 3 differential channels 100 kHz
- 1 counter 1 differential channel 500 kHz
- 2 counters 1 channel 24 Vdc 100 kHz (use digital inputs)
- 2 analogical outputs ±10 Vdc, 12 bit
- 48 x 100 x 120 mm (w x h x l)
RMMT10 (Remote slave module RS485 housed close to DC motor)
- Remote slave module RS485, housed close to DC motor
- 8 digital inputs 24 Vdc PNP
- 4 digital outputs 24 Vdc 100 mA PNP
- 1 counter 3 differential channels 500 kHz
- 1 analogical output ±24 Vdc 6A
- 24 x 100 x 120 mm (w x h x l)
SOFTWARE (optional):
Ours “mindset” it is the opening toward any integrator.
We don’t bind anyone to purchase our softwares.
We are able to provide software and hardware assistance for the systems integration of our modules. Ours wants to be a flexible solution to 360° in the world of the Industrial automation.
1.1 Configuration and Texts (optional)
Configuration tool and text modules:
- CPU and modules editing
- Display status and communication errors
- configuration variables settings
- outputs forcing and inputs display
- Needs Windows® 2000 or next
1.2 Windows Driver
Configurable Communication driver:
- Windows executable communication
- shared memory interface
- continuous or “on demand” jobs
- output forcing, input display and errors analyzing tools
- and errors
- Needs Windows® 2000 or next
1.3 RTX Driver
Configurable realtime communication driver (0,1 ms):
- Communication RTX library (rtdll)
- shared memory realtime interface
- forcing output, display input, and errors analyzing tools
- Needs RTX® 5.5 TCP-IP or next
1.4 SoftLogic hiPlc
softlogic Package:
- 256 kBytes symbolic tags, persistent and VisualBasic, C++, Office, .. accessible programs
- language C++ compiled language (maximun flexibility and performances,
needs commercial compiler)
- ladder interpreted language
- motion control integrated
- configuration and texts tools
- Windows version (10 ms typical scan) e RTX (0,1 ms typical scan)
1.5 SCADA hiPlc
SCADA Package:
- configurable synoptics
- variables log on database or file, based on time or event
- Visualization: alarms realtime and historical graphics
- Ethernet network multistation
- Able to interface programs as VisualBasic, C++, Office, …
2 Services
- HW sales
- SW licensing sales
- training
- developing “turnkey” applications
- full customer assistance
GALLERY
Invalid Displayed Gallery
CONTACTS
Fill out the form below to be contacted by one of our employees in the marketing department.